L1
L3
L2
CONTACTOR
L2L1 L3
G
GROUND
TERMINAL
RED
BLUE
BLK
T1
T3
T2
BLK
J2
BLU
WHT
R1
CONNECT L1, L2 + GROUND
BLOCK
230V, 6KW, 1 PHASE, 26 AMPS
REQUIRES: L1, L2, GRD
30 AMP CIRCUIT BREAKER
BLUE WIRE W/ PUSH ON TERMINAL IS NOT
CONNECTED TO CONTACTOR "L3"
SUPPLIED WITH NEMA 6-30P PLUG
REQUIRES 6-30 RECEPTACLE
230V, 9KW, 1 PHASE, 39 AMPS
REQUIRES: L1, L2, GRD
40 AMP CIRCUIT BREAKER
BLUE WIRE W/ PUSH ON TERMINAL IS
CONNECTED TO CONTACTOR "L3"
HARDWIRED
230V, 18KW, 3 PHASE, 45 AMPS
REQUIRES: L1, L2, L3, GRD
50 AMP CIRCUIT BREAKER
BLUE WIRE W/ PUSH ON TERMINAL IS
CONNECTED TO CONTACTOR "L3"
HARDWIRED
L1
L3
L2
CONTACTOR
G
GROUND
TERMINAL
RED
BLUE
BLK
T1
T3
T2
CONNECT L1, L2 + GROUND
BLOCK
L1
L3
L2
CONTACTOR
G
GROUND
TERMINAL
RED
BLUE
BLK
T1
T3
T2
RED
CONNECT L1, L2, L3 + GROUND
BLOCK
[CHECK MARK INDICATES WIRING OF UNIT]
6KW
R2
6KW
R3
6KW
R1
6KW
R2
6KW
R3
6KW
R1
6KW
R2
6KW
R3
6KW
L1
L3
L2
CONTACTOR
G
GROUND
TERMINAL
RED
BLUE
BLK
T1
T3
T2
RED
R1
CONNECT L1, L2 + GROUND
BLOCK
230V, 12KW, 1 PHASE, 50 AMPS
REQUIRES: L1, L2, GRD
60 AMP CIRCUIT BREAKER
BLUE WIRE W/ PUSH ON TERMINAL IS
CONNECTED TO CONTACTOR "L2"
HARDWIRED
6KW
R2
6KW
R3
6KW
J1
WHT
BLK
J1
WHT
J2
WHT
RED
BLU
RED
L2
L1 L3
L2
L1 L3
L2
L1 L3
J1
WHT
BLK
J2
WHT
RED
BLU
BLU
BLU
J1
WHT
BLK
J2
WHT
BLU
BLU